| 样本 | 血清、血浆、尿液以及组织培养基 |
| 适应物种 | 人血清、血浆、尿液以及组织培养基 |
| 供应商 | 上海研卉生物科技有限公司 |
| 规格 | 96T |
循环中的半胱氨酸蛋白酶抑制剂C(Cystatin C,Cys-C)仅经肾小球滤过而被清除,是一种反映肾小球滤过率变化的内源性标志物。因其分子量小,能自由通过肾小球滤过膜,几乎完全被肾小管重吸收且不被分泌,能很好的替代肌酐而成为一种新的反映GFR的理想标志物。
Cys-C是目前发现的对组织蛋白酶B抑制作用最强的物质,其生物学功能主要是调节半胱氨酸蛋白酶活性。随着科学家对Cys-C的深入研究,发现其不仅在肾脏疾病方面有临床价值,而且还揭示了它与肝脏疾病、糖尿病、肿瘤等具有一定的相关性.
ARBOR ASSAY公司推出的半胱氨酸蛋白酶抑制剂检测试剂盒(CystatinC Human ELISA Kit)将会很好的辅助您肾脏方面的研究。
用途------检测肾损伤特异性标志物;
应用范围广------能够用于检测人来源的血清、血浆、尿液以及组织培养基中的样本;
实验操作简单------能够实现2小时内完成样本的检测。
产品名称 | 货号 |
Hemoglobin High Sensitivity Detection Kits | K013-HX1/HX5 |
Histone Demethylase Fluorescent Activity Kit | K010-F1 |
Retinol Binding Protein Multi-Format EIA Kits | K062-H1/H5 |
Serum Creatinine Detection Kits | KB02-H1/H2 |
Thiol Detection Kit | K005-F1 |
Urea Nitrogen (BUN) Detection Kits | K024-H1/H5 |
Urinary Creatinine Detection Kits | K002-H1/H5 |
The DetectX® Cystatin C Immunoassay Kit is designed to measure Human Cystatin C levels in a variety of biological matrices. This kit uses a microtiter plate coated with a monoclonal to Cystatin C and a native human Cystatin C molecule standard. Samples and standards are added to the plate and after an hour incubation at RT the plate is washed and monoclonal antibody-peroxidase conjugate is added. After a 30-minute incubation at RT, the plate is washed and TMB substrate solution added to each well. The color reaction is read at 450nm.
Cystatin C is a non-glycosylated protein of low molecular weight (13kDa) in the cystatin superfamily. Cystatin C is produced at a constant rate in all nucleated cells. Cystatin C belongs to the cysteine proteinase inhibitor group and is associated with several pathological conditions. Imbalance between Cystatin C and cysteine proteinases is associated with diseases such as inflammation, renal failure, cancer, Alzheimer’s disease, multiple sclerosis and hereditary Cystatin C amyloid angiopathy. Cystatin C is removed from blood plasma by glomerular filtration in the kidneys. It is reabsorbed by the proximal tubular cells and degraded. There is a linear relationship between the reciprocal Cystatin C concentration in plasma and the glomerular filtration rate (GFR). Cystatin C is suggested to be a better marker for GFR than other markers as its serum concentration is not affected by other factors such as age, gender and body mass. There is association of Cystatin C levels with the incidence of myocardial infarction and coronary death, presenting a risk factor for secondary cardiovascular events.