| Type of coating | Ordering information | |||
| NEXTERION®product | Barcode option | Item number | Slides per pack | |
| Reflective optical coating available with most of NEXTERION® functional coatings | HiSens uncoated | None | 1141518 | 25 |
| Label | 1141519 | 25 | ||
| HiSens AStar | None | 1178045 | 25 | |
| Label | 1178046 | 25 | ||
| HiSens A+ | None | 1139673 | 25 | |
| Label | 1141515 | 25 | ||
| HiSens AL | None | 1139827 | 25 | |
| Label | 1141514 | 25 | ||
| HiSens E | None | 1125813 | 25 | |
| Label | 1137332 | 25 | ||
| HiSens H | None | 1141517 | 25 | |
| Label | 1139829 | 25 | ||
| HiSens P | None | 1178051 | 25 | |
| Label | 1178052 | 25 | ||
| Key product features |
| • Significantly improved signal to background ratios for identifying low-expressor genes or low-abundant proteins |
| • Easy implementation with standard slide protocols |
| • Compatible with all common microarray equipment |
| • Reduced target concentrations |
| • Reduced reagents and dye costs |
| • Preservation of Cy3/5™ ratios – comparable to data from conventional slides |
| • Chemically stable reflective coating |
| Suitable probe types |
| The functional coating on NEXTERION® HiSens Slides is identical to the respective coating on NEXTERION® Slides. Please refer to the table in the section “General information coated slides” in order to find the appropriate coating chemistry for your specific application. |
Taken together, these effects can theoretically enhance the fluorescence signal by up to 12.6 times when compared to standard transparent microarray slides.
Increased sensitivity
Significant increases in fluorescent signal intensities and signal-to-background ratios have been demonstrated with the NEXTERION® HiSens E and A+ products, the first two slide surfaces launched by SCHOTT in the HiSens range in 2006 (all slide surfaces are now available). The functional coatings are identical to the standard NEXTERION® slides and were processed with standard slide processing protocols. The results clearly exhibit the same impressive spot size and morphology that users typically associate with NEXTERION® Slide E and Slide A+, but the signal intensity is significantly enhanced thanks to the HiSens coating.
Identical oligonucleotide probes were printed on NEXTERION® HiSens A+ and the standard NEXTERION® Slide A+. The slides were hybridized and scanned on an Axon 4000B scanner with identical settings. Images of the NEXTERION® HiSens reflective coating are compared to standard Slide A+. The NEXTERION® HiSens A+ data was normalized against the standard NEXTERION® Slide A+. An 8 to 10 fold increase in signal-to-background ratios was obtained with the NEXTERION®HiSens reflective coating compared to the standard NEXTERION® Slide A+.