Modification of the deoxy-myoglobin/carbonmonoxy-myoglobin UV-vis assay for reliable determination of CO-release rates from organometallic carbonyl complexes
Anthony J. Atkin,Jason M. Lynam,Benjamin E. Moulton,Philip Sawle,Nicola M. Boyle,Mary T. Pryce,Ian J. S. Fairlamb
Dalton Transactions Pub Date : 04/27/2011 00:00:00 , DOI:10.1039/C0DT01809K
Abstract

The deoxy-myoglobin (deoxy-Mb)/carbonmonoxy-myoglobin (Mb-CO) UV-vis assay is the principal method used for quantifying the rates of CO release from CO-releasing molecules (CO-RMs) that might possess therapeutic benefits. Some issues emerge when the Mb-CO assay is utilized for testing CO-RMs with novel structures, which are comprehensively discussed here for the first time. Two methods for processing raw UV-vis spectroscopic data generated from the assay are presented in this paper.

Graphical abstract: Modification of the deoxy-myoglobin/carbonmonoxy-myoglobin UV-vis assay for reliable determination of CO-release rates from organometallic carbonyl complexes